P1144 NISSAN ALTIMA SEDAN Heated Oxygen Sensor 1 Rich Shift Monitoring

Possible causes
– Faulty Front Heated Oxygen Sensor Bank 1
– Front Heated Oxygen Sensor Bank 1 harness is open or shorted
– Front Heated Oxygen Sensor Bank 1 circuit poor electrical connection
– Inappropriate fuel pressure
– Faulty fuel injectors
– Intake air leaks may be faulty
– Exhaust gas leaks
Tech notes
Replacing the O2 Sensor 1 Bank 1 usually takes care of the problem.
When is the code detected?
An excessively high voltage from the sensor is sent to Engine Control Module (ECM).
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
– High Fuel Consumption
– Excessive Smoke from Exhaust
P1144 NISSAN ALTIMA SEDAN Description

The front heated oxygen sensor (or O2 sensor 1) is placed into the exhaust manifold. It detects the amount of oxygen in the exhaust gas compared to the outside air. The heated oxygen sensor 1 has a closed-end tube made of ceramic zirconia. The zirconia generates voltage from approximately 1V in richer conditions to 0V in leaner conditions. The heated oxygen sensor 1 signal is sent to the Engine Control Module (ECM). The ECM adjusts the injection pulse duration to achieve the ideal air-fuel ratio. The ideal air-fuel ratio occurs near the radical change from 1V to 0V.

 

Compatible with:

2002 NISSAN ALTIMA SEDAN

2003 NISSAN ALTIMA SEDAN

2004 NISSAN ALTIMA SEDAN